Version 02.00, November 2014
44 Rohde & Schwarz R&S
®
BTC Broadcast Test Center
Additive white Gaussian noise (AWGN; R&S
®
BTC-K1040 option)
AWGN can be generated either on path A or B with one R&S
®
BTC-K1040 option. For AWGN to be generated on paths A and B
simultaneously, two R&S
®
BTC-K1040 must be installed.
AWGN is available before fading and after fading to simulate the overall transmission channel.
Addition of an AWGN signal of settable bandwidth and settable C/N ratio or E
b
/N
0
to a wanted signal.
Noise
injection
before fading
after fading
before fading and after fading
distribution density
Gaussian, statistical, separate for I and Q
crest factor
> 18 dB
periodicity
> 48 h
operating modes
add, only
bandwidth
bandwidth coupling
on/off (settable)
receiver bandwidth
1 kHz to 120 MHz (settable)
generated noise bandwidth
100 kHz to 160 MHz (settable)
C/N, E
b
/N
0
setting range
30 dB to +60 dB
resolution
0.1 dB
uncertainty for system bandwidth = symbol
rate, symbol rate < 4 MHz,
24 dB < C/N < 30 dB and
crest factor < 12 dB
< 0.1 dB
System bandwidth
bandwidth for determining noise power
range
1 kHz to 160 MHz
resolution
100 Hz
Extended noise generator (R&S
®
BTC-K1043 option)
Impulsive noise
Pulsed addition of an AWGN signal to the useful signal with settable number of pulses per frame and within settable limits of randomly
distributed pulse intervals.
Impulsive noise can be generated either on path A or B with one R&S
®
BTC-K1043 option. For impulsive noise to be generated on
paths A and B simultaneously, two R&S
®
BTC-K1043 must be installed.
Impulsive noise
required option
R&S
®
BTC-K1043
AWGN signal data
see R&S
®
BTC-K1040 option
Pulse generator
Frame
duration
10 ms, 100 ms, 1000 ms
Pulse
duration
0.25 µs, fixed
Pulses per frame
setting range
1 to 40000
Minimum pulse interval
for number of pulses > 1
setting range
0.25 µs to 16 ms
resolution
0.25 µs
Maximum pulse interval
for number of pulses > 1
setting range
0.25 µs to 16 ms
resolution
0.25 µs
Distribution of pulse intervals
function
PRBS